Frequency converter

EFC 3610

 

 
   
  • Power range 1 x AC 230 V 0.4 kW to 3 x AC 400 V 22.0 kW
  • Integrated brake chopper and mains filter
  • Integrated operating panel for simple, fast commissioning
  • Expandability through I/O and fieldbus modules

 

 
Search
   
Search
 
Documentation  

Instructions   
PDF version  

PDF version   

Technical dataDimensionsCADDownloadOrder details

 
  EFC3610-0K40-1P2 EFC3610-0K75-1P2 EFC3610-1K50-1P2 EFC3610-2K20-1P2 EFC3610-0K40-3P4 EFC3610-0K75-3P4 EFC3610-1K50-3P4 EFC3610-2K20-3P4
Performance data
Rated output
HD operation
[kW] 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2
Continuous rated current
HD operation
[A] 2.4 4.1 7.3 10.1 1.3 2.3 4 5.6
Motor rated voltage

Three phase, 0 V ... mains voltage

Output frequency

0 ... 400 Hz

Mains voltage 1 AC 1 AC 200 … 240 V (-10 % / +10 %) -
3 AC - 3 AC 380 … 480 V (-15 % / +10 %)
Frequency

50 ... 60 Hz (±5 %)

Overload capacity
HD operation

150 % for 60 s, 200 % for 1 s

Brake chopper / resistor
Braking resistance

External

Brake chopper

Internal up to 22 kW

Ambient conditions
Permissible temperature (operation)

-10 ... +45 °C (Derating 1.5 % of the output power per 1 °C from 45 ... 55 °C)

Permissible relative humidity (operation)

< 90 % (no condensation)

Max. installation height

1000 m (> 1000 m Derating 1 % of the output power pro 100 m)

Protection category

IP 20

Functions
Control technology

V/f

Pulse width modulation (PWM), adjustable in 1 kHz steps [kHz]

1 ... 15

Speed control range Without pulse generator

1 : 50

Start-up torque V/f

100% at 1.5 Hz; 150% at 3 Hz

Frequency resolution Digital

0.01 Hz

Analog

1/1000 of the output frequency

V/f curve

linear, quadratic, freely definable

Ramps

linear, S-curve

DC disc brake Start frequency

0 ... 50 Hz

Braking time

0 ... 10 s

Automatic PWM frequency adjustment

load-dependent adaptation of PWM frequency

Integrated control

integrated step switching mechanism

Frequency setting tolerance Analog

0.4 %

Digital

0.04 %

Controller

PID

Bus systems

Modbus RTU (with Multi-Ethernet Modbus TCP)

PROFIBUS, CANopen, Multi-Ethernet (ext. options)

Status messages via digital outputs

Operation, target value achieved, etc.

Number of digital inputs
24 VDC

5 (of which 1x pulse train 50 kHz)

Number of digital outputs
24 VDC / 50 mA

1 (pulse train 32 kHz)

Number of relay outputs 
230 VAC / 30 VDC / 3 A

1

Number of analog inputs
0 ... 10 V or 0 ... 20 mA

2

Number of analog outputs
0 ... 10 V or 0 ... 20 mA

1

Display

Dust cover with 4 diagnostic LED

LED 5 digit (optional)

LCD (optional)

Status LED

Rotation direction and operating status

Weight
Weight [kg] 1.5 1.9 2.6 1.5 1.9
Norms and Standards
Certification

CE
UL
cUL
EAC
C-Tick (RCM)

 
  EFC3610-3K00-3P4 EFC3610-4K00-3P4 EFC3610-5K50-3P4 EFC3610-7K50-3P4 EFC3610-11K0-3P4 EFC3610-15K0-3P4 EFC3610-18K5-3P4 EFC3610-22K0-3P4
Performance data
Rated output
HD operation
[kW] 3 4 5.5 7.5 11 15 18.5 22
Rated output
ND operation
[kW] - 7.5 11 15 18.5 22 30
Continuous rated current
HD operation
[A] 7.4 9.7 12.7 16.8 24.3 32.4 39.2 45
Continuous rated current
ND operation
[A] - 16.8 24.3 32.4 39.2 45 60.8
Motor rated voltage

Three phase, 0 V ... mains voltage

Output frequency

0 ... 400 Hz

Mains voltage 3 AC

3 AC 380 … 480 V (-15 % / +10 %)

Frequency

50 ... 60 Hz (±5 %)

Overload capacity
HD operation

150 % for 60 s, 200 % for 1 s

Brake chopper / resistor
Braking resistance

External

Brake chopper

Internal up to 22 kW

Ambient conditions
Permissible temperature (operation)

-10 ... +45 °C (Derating 1.5 % of the output power per 1 °C from 45 ... 55 °C)

Permissible relative humidity (operation)

< 90 % (no condensation)

Max. installation height

1000 m (> 1000 m Derating 1 % of the output power pro 100 m)

Protection category

IP 20

Functions
Control technology

V/f

Pulse width modulation (PWM), adjustable in 1 kHz steps [kHz]

1 ... 15

Speed control range Without pulse generator

1 : 50

Start-up torque V/f

100% at 1.5 Hz; 150% at 3 Hz

Frequency resolution Digital

0.01 Hz

Analog

1/1000 of the output frequency

V/f curve

linear, quadratic, freely definable

Ramps

linear, S-curve

DC disc brake Start frequency

0 ... 50 Hz

Braking time

0 ... 10 s

Automatic PWM frequency adjustment

load-dependent adaptation of PWM frequency

Integrated control

integrated step switching mechanism

Frequency setting tolerance Analog

0.4 %

Digital

0.04 %

Controller

PID

Bus systems

Modbus RTU (with Multi-Ethernet Modbus TCP)

PROFIBUS, CANopen, Multi-Ethernet (ext. options)

Status messages via digital outputs

Operation, target value achieved, etc.

Number of digital inputs
24 VDC

5 (of which 1x pulse train 50 kHz)

Number of digital outputs
24 VDC / 50 mA

1 (pulse train 32 kHz)

Number of relay outputs 
230 VAC / 30 VDC / 3 A

1

Number of analog inputs
0 ... 10 V or 0 ... 20 mA

2

Number of analog outputs
0 ... 10 V or 0 ... 20 mA

1

Display

Dust cover with 4 diagnostic LED

LED 5 digit (optional)

LCD (optional)

Status LED

Rotation direction and operating status

Weight
Weight [kg] 2.6 3.9 4.3 5.7 6.4 8 8.5
Norms and Standards
Certification

CE
UL
cUL
EAC
C-Tick (RCM)

 

Electric Drives and Controls, Online Version, Last Updated #version#

© Bosch Rexroth AG, Subject to Change

(*) là thông tin bắt buộc
(*)
(*)
(*)
Nerfew
29/10/2023 22:51:25
Teaching about medication safety should include discussions on the potential risks of polypharmacy buy dapoxetine online
yeezy outlet
29/10/2023 06:24:43
You made some decent factors there. I looked on the web for the difficulty and located most individuals will go together with with your website. yeezy outlet http://www.yeezysneakers.us.org
kobe shoes
28/10/2023 17:18:37
I and also my buddies appeared to be reading through the excellent tactics on your web page and then got a horrible feeling I never expressed respect to the blog owner for those secrets. The ladies appeared to be for that reason very interested to learn all of them and have now absolutely been loving those things. Appreciation for really being well considerate and then for picking out such fabulous subjects millions of individuals are really desirous to be aware of. My honest regret for not sayi
業界最高品質ブランドコピー専門ショップ最新
28/10/2023 08:03:35
Frequency Converter
0 VNĐ
Frequency Converter
0 VNĐ
Frequency Converter
0 VNĐ