EFC 3610 - Frequency Converter
Giá bán: 0 VNĐ/cái
Số lượng
Giá thị trường: 0 VNĐ /cái Tiết kiệm: 0.0 %

Frequency converter

EFC 3610

 

 
   
  • Power range 1 x AC 230 V 0.4 kW to 3 x AC 400 V 22.0 kW
  • Integrated brake chopper and mains filter
  • Integrated operating panel for simple, fast commissioning
  • Expandability through I/O and fieldbus modules

 

 
Search
   
Search
 
Documentation  

Instructions   
PDF version  

PDF version   

Technical dataDimensionsCADDownloadOrder details

 
  EFC3610-0K40-1P2 EFC3610-0K75-1P2 EFC3610-1K50-1P2 EFC3610-2K20-1P2 EFC3610-0K40-3P4 EFC3610-0K75-3P4 EFC3610-1K50-3P4 EFC3610-2K20-3P4
Performance data
Rated output
HD operation
[kW] 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2
Continuous rated current
HD operation
[A] 2.4 4.1 7.3 10.1 1.3 2.3 4 5.6
Motor rated voltage

Three phase, 0 V ... mains voltage

Output frequency

0 ... 400 Hz

Mains voltage 1 AC 1 AC 200 … 240 V (-10 % / +10 %) -
3 AC - 3 AC 380 … 480 V (-15 % / +10 %)
Frequency

50 ... 60 Hz (±5 %)

Overload capacity
HD operation

150 % for 60 s, 200 % for 1 s

Brake chopper / resistor
Braking resistance

External

Brake chopper

Internal up to 22 kW

Ambient conditions
Permissible temperature (operation)

-10 ... +45 °C (Derating 1.5 % of the output power per 1 °C from 45 ... 55 °C)

Permissible relative humidity (operation)

< 90 % (no condensation)

Max. installation height

1000 m (> 1000 m Derating 1 % of the output power pro 100 m)

Protection category

IP 20

Functions
Control technology

V/f

Pulse width modulation (PWM), adjustable in 1 kHz steps [kHz]

1 ... 15

Speed control range Without pulse generator

1 : 50

Start-up torque V/f

100% at 1.5 Hz; 150% at 3 Hz

Frequency resolution Digital

0.01 Hz

Analog

1/1000 of the output frequency

V/f curve

linear, quadratic, freely definable

Ramps

linear, S-curve

DC disc brake Start frequency

0 ... 50 Hz

Braking time

0 ... 10 s

Automatic PWM frequency adjustment

load-dependent adaptation of PWM frequency

Integrated control

integrated step switching mechanism

Frequency setting tolerance Analog

0.4 %

Digital

0.04 %

Controller

PID

Bus systems

Modbus RTU (with Multi-Ethernet Modbus TCP)

PROFIBUS, CANopen, Multi-Ethernet (ext. options)

Status messages via digital outputs

Operation, target value achieved, etc.

Number of digital inputs
24 VDC

5 (of which 1x pulse train 50 kHz)

Number of digital outputs
24 VDC / 50 mA

1 (pulse train 32 kHz)

Number of relay outputs 
230 VAC / 30 VDC / 3 A

1

Number of analog inputs
0 ... 10 V or 0 ... 20 mA

2

Number of analog outputs
0 ... 10 V or 0 ... 20 mA

1

Display

Dust cover with 4 diagnostic LED

LED 5 digit (optional)

LCD (optional)

Status LED

Rotation direction and operating status

Weight
Weight [kg] 1.5 1.9 2.6 1.5 1.9
Norms and Standards
Certification

CE
UL
cUL
EAC
C-Tick (RCM)

 
  EFC3610-3K00-3P4 EFC3610-4K00-3P4 EFC3610-5K50-3P4 EFC3610-7K50-3P4 EFC3610-11K0-3P4 EFC3610-15K0-3P4 EFC3610-18K5-3P4 EFC3610-22K0-3P4
Performance data
Rated output
HD operation
[kW] 3 4 5.5 7.5 11 15 18.5 22
Rated output
ND operation
[kW] - 7.5 11 15 18.5 22 30
Continuous rated current
HD operation
[A] 7.4 9.7 12.7 16.8 24.3 32.4 39.2 45
Continuous rated current
ND operation
[A] - 16.8 24.3 32.4 39.2 45 60.8
Motor rated voltage

Three phase, 0 V ... mains voltage

Output frequency

0 ... 400 Hz

Mains voltage 3 AC

3 AC 380 … 480 V (-15 % / +10 %)

Frequency

50 ... 60 Hz (±5 %)

Overload capacity
HD operation

150 % for 60 s, 200 % for 1 s

Brake chopper / resistor
Braking resistance

External

Brake chopper

Internal up to 22 kW

Ambient conditions
Permissible temperature (operation)

-10 ... +45 °C (Derating 1.5 % of the output power per 1 °C from 45 ... 55 °C)

Permissible relative humidity (operation)

< 90 % (no condensation)

Max. installation height

1000 m (> 1000 m Derating 1 % of the output power pro 100 m)

Protection category

IP 20

Functions
Control technology

V/f

Pulse width modulation (PWM), adjustable in 1 kHz steps [kHz]

1 ... 15

Speed control range Without pulse generator

1 : 50

Start-up torque V/f

100% at 1.5 Hz; 150% at 3 Hz

Frequency resolution Digital

0.01 Hz

Analog

1/1000 of the output frequency

V/f curve

linear, quadratic, freely definable

Ramps

linear, S-curve

DC disc brake Start frequency

0 ... 50 Hz

Braking time

0 ... 10 s

Automatic PWM frequency adjustment

load-dependent adaptation of PWM frequency

Integrated control

integrated step switching mechanism

Frequency setting tolerance Analog

0.4 %

Digital

0.04 %

Controller

PID

Bus systems

Modbus RTU (with Multi-Ethernet Modbus TCP)

PROFIBUS, CANopen, Multi-Ethernet (ext. options)

Status messages via digital outputs

Operation, target value achieved, etc.

Number of digital inputs
24 VDC

5 (of which 1x pulse train 50 kHz)

Number of digital outputs
24 VDC / 50 mA

1 (pulse train 32 kHz)

Number of relay outputs 
230 VAC / 30 VDC / 3 A

1

Number of analog inputs
0 ... 10 V or 0 ... 20 mA

2

Number of analog outputs
0 ... 10 V or 0 ... 20 mA

1

Display

Dust cover with 4 diagnostic LED

LED 5 digit (optional)

LCD (optional)

Status LED

Rotation direction and operating status

Weight
Weight [kg] 2.6 3.9 4.3 5.7 6.4 8 8.5
Norms and Standards
Certification

CE
UL
cUL
EAC
C-Tick (RCM)

 

Electric Drives and Controls, Online Version, Last Updated #version#

© Bosch Rexroth AG, Subject to Change

(*) là thông tin bắt buộc
(*)
(*)
(*)
Sheddy
16/06/2023 20:32:37
Researchers are investigating the effects of chronic medication use, such as antihistamines and antipsychotics, on erectile function. Collaborative medication management and regular monitoring can help optimize treatment plans and minimize sexual side effects. fildena price buy fildena 50mg online
Sheddy
16/06/2023 18:48:29
Sexually transmitted infections, such as syphilis, can have serious health consequences if left untreated, affecting various organ systems in men. order sildenafil 100mg sale
Sheddy
16/06/2023 18:46:22
Researchers are investigating the effects of chronic gastrointestinal disorders, such as inflammatory bowel disease and irritable bowel syndrome, on erectile function. Addressing gastrointestinal health may positively impact ED outcomes in individuals with these conditions. order sildenafil 100mg pills sildenafil without prescription cheap fildena 100
Ericklaf
15/06/2023 15:48:13
https://whyride.info/ - whyride
Frequency Converter
0 VNĐ
Frequency Converter
0 VNĐ
Frequency Converter
0 VNĐ