VN EN
 
  0941 827 888 Thứ 2-7 : 8-20H;
Chủ nhật : 8-17H
 
 
  [email protected] Trả lời 30' trong giờ hành chính  

 

Email
Mật khẩu
Trang chủ
TG-500N to TG-250kN - Compression and Tensile Testing Machine TG series
Giá bán: 0 VNĐ/cái
Số lượng
Giá thị trường: 0 VNĐ /cái Tiết kiệm: 0.0 %

Feature

  • Multiple function and high accuracy combined
    with simple setup procedures for increased testing efficiency
       
      Lineup of nine models available (500 N, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN, 100 kN, 250 kN) to suit test force requirements.
      The front control panel is designed with displays and switches arranged together for ease of use.
      Simply connect a load cell with automatic calibration and automatic zero resetting functions, eliminating the need for adjustment.
      Supports accuracy of ±1% of indicated value (JIS Class 1) or ±0.5% of indicated value (JIS Class 0.5) in range 1/1 to 1/500 of load cell capacity.
      Three manual speeds for position setting before testing, each freely settable.
      Compact, lightweight design eliminates constraints on installation site.
Specifications  
Model TG-250kN TG-100kN TG-50kN
TG-20kN
TG-10kN
TG-5kN
TG-2kN
TG-1kN
TG-500N
Maximum test force 250 kN 100 kN 50 kN 
/ 20 kN
10 kN / 
5 kN / 2 kN
1 kN 
/ 500 N
Test force measure -ment range
(Note 1)
0.1 N ~ 250 kN 0.1 N ~ 100 kN 0.1 N ~ 50 kN
0.1 N ~ 20 kN
0.1 N to 10 kN
0.1 N ~ 5 kN
0.1 N ~ 2 kN
0.1 N ~ 1 kN
0.1 N ~ 500 N
Test space Tensile/compression testing beneath the movable crosshead
(A model is available allowing tensile testing above the movable crosshead. (Optional))
Loading method Constant-speed strain loading with high-accuracy AC servo motor and backlash-free precision ball screw.
Crosshead speed /permissible
test force
Within the max. test force over the entire speed range.
Test force measuring accuracy ±1% of indicated value in range 1/1 to 1/500 of load cell capacity for both tensile and compression
(A high-accuracy model with ±0.5% of indicated value is available as an option.)
Applies to load cell with rated output of 3 mV/V
Applicable standards JIS B 7721 Class 1 or Class 0.5 and ISO7500-1 Class 1 or Class 0.5
Effective test width (Note 2) (mm) 600 600 420 420 300
Crosshead stroke (mm) 1 550 1 350 1 010 895 770
Maximum mounting space *3) (mm) 1 690 1 555 1 155 1 030 925
Tensile stroke (Note 4) (mm) 620 850 460/540 545/655
/655
550/570
Crosshead speed
[standard model]
[Extended speed range model] (mm/min)
0.05 to 500 17 steps
0.005 to 500 21 steps
0.05 to1 000 18 steps
0.005 to1 000 22 steps
Crosshead speed accuracy (Note 5) ±0.1% over entire speed range 
(Excluding custom and manual speed)
Test force/crosshead position display Test force: 5-digit digital display. 
Movable crosshead position: 5 1/2-digit digital display ±199999
Crosshead position display accuracy ±0.1% of indicated value. (±0.01 mm up to ±10 mm)
Cycle count display 4-digit digital display, selection display on position display
Cycle control 
(Note 6)
Position setting, test force setting, and combined setting possible. 
With cycle number preset function.
Return function Test speed or rapid return speed (customer setting) can be selected. 
With zero-overshoot function (stops at position [0])
Sample rupture detection function Sensitivity can be set as desired. 
(Can be set to stop movable crosshead, reverse, or ignore on detection.)
Test force
amplifier
(Measurement scale)

:

Seven steps: ×1, ×2, ×5, ×10, ×20, ×50, ×100 
(Auto range function: optional)
Auto zero

:

Provided (2 modes: All range auto zero and Set range auto zero)

Calibration

:

Automatic calibration using data registration
Outline dimensions 
(W x H x D)(mm)
1 400 x 2 450
x 894
1 172 x 2 192
x 720
795 x 1 515
x 495
760 x 1 345
x 370
620 x 1 183
x 370
Weight(Approx. kg) 1 200 900 310 130 70
Power supply 3-phase AC200 V±20 V 1-phase AC100 V±10 V
(TG-10kN : 3-phase AC200 V±20 V)
Power consumption
(W)
7 k 5 k 1.5 k 400
(TG-10kN : 750)
200
Operating temp. /humidity range Temperature 5 ℃ to 40 ℃, Humidity 20 % to 80 %RH 
(with no condensation)
  • Note 1: The test force measurement range varies depending on the rated capacity of the load cell used.
    Note 2: Testing machines are available with large effective width.
    Note 3: Models are available with extended stroke.
    Note 4: Tensile testing stroke is for maximum test force capacity load cell with the (optional) chuck mounted.
    Note 5: Extended speed range crosshead speed accuracy is the accuracy in the range 0.05 to 500 mm/min.
    Note 6: Use a reciprocating speed not exceeding 3 cycles/min for cycle testing.
Download
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
TG-250kN (1.3MB)
TG-100kN (1.3MB)
TG-50kN (1.1MB)
TG-20kN (1.1MB)
TG-10kN (1.1MB)
TG-5kN (1.1MB)
TG-2kN (1.1MB)
TG-1kN (1.1MB)
TG-500N (1.1MB)
TG-250kN (122KB)
TG-100kN (93KB)
TG-50kN (90KB) 
TG-20kN (90KB)
TG-10kN (94KB) 
TG-5kN (92KB) 
TG-2kN (102KB)
TG-1kN (93KB) 
TG-500N (90KB)
---
(*) là thông tin bắt buộc
(*)
(*)
(*)
Equilibradobut
17/07/2025 01:42:34
vibracion de motor Aparatos de ajuste: importante para el operacion estable y productivo de las equipos. En el entorno de la ciencia actual, donde la rendimiento y la fiabilidad del sistema son de gran relevancia, los sistemas de ajuste cumplen un rol vital. Estos sistemas especializados estan disenados para balancear y estabilizar piezas rotativas, ya sea en maquinaria de fabrica, vehiculos de movilidad o incluso en aparatos caseros. Para los tec
JorgeOxype
16/07/2025 06:17:49
equilibrando Equipos de ajuste: fundamental para el funcionamiento fluido y productivo de las equipos. En el campo de la innovacion actual, donde la efectividad y la estabilidad del equipo son de suma trascendencia, los dispositivos de balanceo cumplen un tarea esencial. Estos aparatos dedicados estan concebidos para equilibrar y regular partes rotativas, ya sea en dispositivos industrial, medios de transporte de transporte o incluso en dispositivos do
Equilibradobut
15/07/2025 11:19:08
Vibracion del motor Dispositivos de calibracion: esencial para el funcionamiento fluido y efectivo de las maquinas. En el entorno de la ciencia actual, donde la productividad y la seguridad del dispositivo son de gran significancia, los aparatos de balanceo tienen un funcion crucial. Estos dispositivos adaptados estan concebidos para equilibrar y estabilizar componentes giratorias, ya sea en dispositivos manufacturera, automoviles de movilidad o inclus
Samuelsup
15/07/2025 09:45:47
Diagnostico de equipos Aparatos de balanceo: fundamental para el operacion suave y efectivo de las equipos. En el campo de la innovacion actual, donde la efectividad y la estabilidad del aparato son de maxima importancia, los equipos de calibracion tienen un tarea esencial. Estos sistemas especificos estan disenados para calibrar y estabilizar piezas rotativas, ya sea en herramientas de fabrica, vehiculos de desplazamiento o incluso en electrodomestico
Equilibradobut
15/07/2025 07:15:24
Diagnostico de equipos Dispositivos de ajuste: fundamental para el rendimiento suave y productivo de las dispositivos. En el entorno de la tecnologia avanzada, donde la productividad y la fiabilidad del dispositivo son de alta importancia, los aparatos de balanceo tienen un rol crucial. Estos dispositivos dedicados estan desarrollados para balancear y asegurar partes dinamicas, ya sea en dispositivos productiva, vehiculos de traslado o incluso en apara
Load Test Stand LTS-50NB / LTS-200NB / LTS-500NB / LTS-1kNB
0 VNĐ
Technograph TGE series
0 VNĐ
Technograph TGI series
0 VNĐ