VN EN
 
  0941 827 888 Thứ 2-7 : 8-20H;
Chủ nhật : 8-17H
 
 
  [email protected] Trả lời 30' trong giờ hành chính  

 

Email
Mật khẩu
Trang chủ
TG-500N to TG-250kN - Compression and Tensile Testing Machine TG series
Giá bán: 0 VNĐ/cái
Số lượng
Giá thị trường: 0 VNĐ /cái Tiết kiệm: 0.0 %

Feature

  • Multiple function and high accuracy combined
    with simple setup procedures for increased testing efficiency
       
      Lineup of nine models available (500 N, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN, 100 kN, 250 kN) to suit test force requirements.
      The front control panel is designed with displays and switches arranged together for ease of use.
      Simply connect a load cell with automatic calibration and automatic zero resetting functions, eliminating the need for adjustment.
      Supports accuracy of ±1% of indicated value (JIS Class 1) or ±0.5% of indicated value (JIS Class 0.5) in range 1/1 to 1/500 of load cell capacity.
      Three manual speeds for position setting before testing, each freely settable.
      Compact, lightweight design eliminates constraints on installation site.
Specifications  
Model TG-250kN TG-100kN TG-50kN
TG-20kN
TG-10kN
TG-5kN
TG-2kN
TG-1kN
TG-500N
Maximum test force 250 kN 100 kN 50 kN 
/ 20 kN
10 kN / 
5 kN / 2 kN
1 kN 
/ 500 N
Test force measure -ment range
(Note 1)
0.1 N ~ 250 kN 0.1 N ~ 100 kN 0.1 N ~ 50 kN
0.1 N ~ 20 kN
0.1 N to 10 kN
0.1 N ~ 5 kN
0.1 N ~ 2 kN
0.1 N ~ 1 kN
0.1 N ~ 500 N
Test space Tensile/compression testing beneath the movable crosshead
(A model is available allowing tensile testing above the movable crosshead. (Optional))
Loading method Constant-speed strain loading with high-accuracy AC servo motor and backlash-free precision ball screw.
Crosshead speed /permissible
test force
Within the max. test force over the entire speed range.
Test force measuring accuracy ±1% of indicated value in range 1/1 to 1/500 of load cell capacity for both tensile and compression
(A high-accuracy model with ±0.5% of indicated value is available as an option.)
Applies to load cell with rated output of 3 mV/V
Applicable standards JIS B 7721 Class 1 or Class 0.5 and ISO7500-1 Class 1 or Class 0.5
Effective test width (Note 2) (mm) 600 600 420 420 300
Crosshead stroke (mm) 1 550 1 350 1 010 895 770
Maximum mounting space *3) (mm) 1 690 1 555 1 155 1 030 925
Tensile stroke (Note 4) (mm) 620 850 460/540 545/655
/655
550/570
Crosshead speed
[standard model]
[Extended speed range model] (mm/min)
0.05 to 500 17 steps
0.005 to 500 21 steps
0.05 to1 000 18 steps
0.005 to1 000 22 steps
Crosshead speed accuracy (Note 5) ±0.1% over entire speed range 
(Excluding custom and manual speed)
Test force/crosshead position display Test force: 5-digit digital display. 
Movable crosshead position: 5 1/2-digit digital display ±199999
Crosshead position display accuracy ±0.1% of indicated value. (±0.01 mm up to ±10 mm)
Cycle count display 4-digit digital display, selection display on position display
Cycle control 
(Note 6)
Position setting, test force setting, and combined setting possible. 
With cycle number preset function.
Return function Test speed or rapid return speed (customer setting) can be selected. 
With zero-overshoot function (stops at position [0])
Sample rupture detection function Sensitivity can be set as desired. 
(Can be set to stop movable crosshead, reverse, or ignore on detection.)
Test force
amplifier
(Measurement scale)

:

Seven steps: ×1, ×2, ×5, ×10, ×20, ×50, ×100 
(Auto range function: optional)
Auto zero

:

Provided (2 modes: All range auto zero and Set range auto zero)

Calibration

:

Automatic calibration using data registration
Outline dimensions 
(W x H x D)(mm)
1 400 x 2 450
x 894
1 172 x 2 192
x 720
795 x 1 515
x 495
760 x 1 345
x 370
620 x 1 183
x 370
Weight(Approx. kg) 1 200 900 310 130 70
Power supply 3-phase AC200 V±20 V 1-phase AC100 V±10 V
(TG-10kN : 3-phase AC200 V±20 V)
Power consumption
(W)
7 k 5 k 1.5 k 400
(TG-10kN : 750)
200
Operating temp. /humidity range Temperature 5 ℃ to 40 ℃, Humidity 20 % to 80 %RH 
(with no condensation)
  • Note 1: The test force measurement range varies depending on the rated capacity of the load cell used.
    Note 2: Testing machines are available with large effective width.
    Note 3: Models are available with extended stroke.
    Note 4: Tensile testing stroke is for maximum test force capacity load cell with the (optional) chuck mounted.
    Note 5: Extended speed range crosshead speed accuracy is the accuracy in the range 0.05 to 500 mm/min.
    Note 6: Use a reciprocating speed not exceeding 3 cycles/min for cycle testing.
Download
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
TG-250kN (1.3MB)
TG-100kN (1.3MB)
TG-50kN (1.1MB)
TG-20kN (1.1MB)
TG-10kN (1.1MB)
TG-5kN (1.1MB)
TG-2kN (1.1MB)
TG-1kN (1.1MB)
TG-500N (1.1MB)
TG-250kN (122KB)
TG-100kN (93KB)
TG-50kN (90KB) 
TG-20kN (90KB)
TG-10kN (94KB) 
TG-5kN (92KB) 
TG-2kN (102KB)
TG-1kN (93KB) 
TG-500N (90KB)
---
(*) là thông tin bắt buộc
(*)
(*)
(*)
Josephesset
09/07/2025 08:00:25
equilibrado estatico Equipos de equilibrado: fundamental para el funcionamiento suave y eficiente de las máquinas. En el ámbito de la ciencia avanzada, donde la rendimiento y la seguridad del aparato son de gran relevancia, los dispositivos de balanceo desempeñan un tarea crucial. Estos dispositivos adaptados están desarrollados para ajustar y regular elementos giratorias, ya sea en herramientas productiva, vehículos de transporte o incluso en apa
Samuelsup
08/07/2025 12:06:28
Holgura mecanica Equipos de calibracion: importante para el rendimiento fluido y optimo de las maquinas. En el entorno de la ciencia avanzada, donde la efectividad y la estabilidad del equipo son de maxima significancia, los dispositivos de ajuste tienen un papel fundamental. Estos dispositivos especializados estan desarrollados para balancear y estabilizar piezas moviles, ya sea en dispositivos manufacturera, medios de transporte de movilidad o inclus
Samuelsup
08/07/2025 05:01:09
reparacion de maquinaria agricola Sistemas de balanceo: clave para el funcionamiento uniforme y productivo de las dispositivos. En el campo de la tecnologia contemporanea, donde la rendimiento y la estabilidad del dispositivo son de maxima relevancia, los sistemas de calibracion cumplen un funcion fundamental. Estos equipos adaptados estan concebidos para balancear y fijar componentes rotativas, ya sea en herramientas productiva, medios de transporte d
Samuelsup
07/07/2025 11:05:39
Holgura mecanica Aparatos de equilibrado: clave para el rendimiento uniforme y efectivo de las dispositivos. En el ambito de la tecnologia moderna, donde la rendimiento y la seguridad del equipo son de maxima significancia, los equipos de equilibrado cumplen un papel crucial. Estos equipos adaptados estan desarrollados para balancear y estabilizar elementos giratorias, ya sea en equipamiento de fabrica, automoviles de desplazamiento o incluso en equipo
Load Test Stand LTS-50NB / LTS-200NB / LTS-500NB / LTS-1kNB
0 VNĐ
Technograph TGE series
0 VNĐ
Technograph TGI series
0 VNĐ