The testing instruments of the EPLEXOR® series up to ±500 N enable the dynamic mechanical (or static) characterization of a wide range of different materials including elastomers and polymers, composites, metals, glasses, ceramics, biomaterials and foods, adhesives, and liquids.

The modular design of the high-force DMA/DMTA systems allows for measurements in the tension, compression, bending and shearing modes. The testing machines in this series differ from each other mainly in terms of their maximum dynamic force ranges of ±25 N, ±100 N, ±150 N and ±500 N.

Various add-on options make these testing machines a safe investment for the long-term.

All testing machines in this series are conform to standards such as DIN 53513, ISO 6721/1, ISO 6721/4, ISO 6721/5, ISO 6721/6, ISO 4664, ASTM D4065, and ASTM D4473.  

Request InformationData SheetBrochure

 


Flexible and Set for the Future
...by means of a variety of force and strain sensors as well as furnaces which allow for easy upgrades to the basic system at any time after the first installation

High Force Levels 
...allowing for static loads up to 500 N (optional: up to 1500 N) and dynamic loads up to ± 500 N; especially meaningful for investigations on curable resins, elastomers, composites, metals, glasses or ceramics

Two Independent Drives 
...featuring a servo motor for static and a shaker for dynamic loads

Interchangeable Force Sensors 
...which can be easily changed out by the operator; nominal loads available ranging from ±10 N to ±2500 N

24/7 Operation via the Automatic Sample Changer 
...for tension, compression and bending samples across the entire temperature range around the clock

Optimized for Temperature Sweeps on Large Samples 
...thanks to uniform heating of even large samples with low thermal conductivity (e.g., large rubber specimens)

Highly Economic LN2 Cooling 
...for low liquid nitrogen consumption

Simultaneous Determination of Dynamic Mechanical and Dielectric Material Properties     

Key Technical Data

(subject to change)

  • Temperature range:  
    -160°C to 1500°C (temperature range covered by three furnaces)
  • Frequency range:  
    0.01 Hz to 100 Hz; optional 0.0001 Hz and 200 Hz
  • Static force range:
    up to 500 N and optional 1500 N
  • Dynamic force range:
    ± 500 N, ± 150 N,  ± 100 N, ± 25 N
  • Force sensor:
    interchangeable; nominal forces available from ±10 N to ±2500 N
  • Blade springs:
    counteract the static forces and allow for independent superposition of the dynamic forces
  • Static displacement:
    60 mm
  • Dynamic displacement:
    available strain sensors: ± 1.5 mm, ± 3 mm and ± 6 mm (depending on the EPLEXOR model)
  • Supplementary analysis modes:
    creep, relaxation, fatigue, heat build-up, curing, tensile tests, rolling resistance of tires, tackifying
  • Max. sample dimensions (inside the standard furnace):
    • tension:  80 mm x 10 mm x 10 mm (80 mm length)
    • shear: ∅ 4 mm to 20 mm (standard: 10 mm)
    • 3-point bending:  up to 70 mm free bending length (up to 120 mm sample length)
  • Sample holders:  
    3/4-point bending, tension, shear, compression, single/dual cantilever bending, asymmetric bending, curing/liquids, immersion tests, for fiber bundles; holder for T and H tests (tire cords)
  • Automatic sample length detection or thickness determination possible in tensile, compression and bending geometries  

Software

The comprehensive EPLEXOR® software is based on Windows operating systems. The extensive software package comprises data and curve analyses, hysteresis representation, master curve calculations, etc. 
It also includes specific templates for tension, compression or bending tests.

The software features include:

  • Frequency sweep of 0.001 Hz to 100 Hz (optional 0.0001 Hz and 200 Hz)
  • Temperature sweep (controlled temperature variation at fixed frequency)
  • Time sweep from 1 s to 107 s
  • Correlated temperature and frequency sweep at isothermal steps
  • Correlated dynamic and static strain amplitude sweeps; equidistantly or logarithmically subdivided
  • Master curves (TTS, WLF, numeric mastering), segment tests
  • Evaluation of complex modulus (E*, G*), storage modulus (E’, G’), loss modulus (E’’, G’’) damping factor (t and δ) by temperature sweeps, strain and force sweeps, time sweeps, glass transition temperature, and optional creep, relaxation, fatigue, energy loss, hysteresis, Payne/Mullins effect analysis and crack growth testing
  • Determination of the thermal expansion in tension mode (optional)
  • Prediction of the rolling resistance of tires (optional)  

Accessories

Sample Holders for a Variety of Applications 
...from liquids via reinforced thermosets to metals and ceramics — all materials can be investigated with the EPLEXOR®.  

Simultaneous DMA/DMTA and DEA 
...for the investigation of transport and relaxation processes on the molecular level.  

UV Add-On 
...for studying reactions which are irradiated by UV light.  

Humidity Generator (HYGROMATOR®
...add-on serves to investigate the water uptake of samples such as plastics and biopolymers. With the humidity generator, it is possible to create relative humidity values of between 5% and 95% in the temperature range between 5°C and 95°C.  

Immersion Bath 
...even for measurements in the tension, compression and bending mode; for the investigation of aging or plasticizer effects caused by contact with water or oil.

Goodrich Flexometer Module
...for the optimization of the thermal properties and life cycle of tire mixtures; applies a cyclic load and measures the resulting temperature change due to heat build-up.  

Cooling Options 
...two different cooling systems are available including liquid nitrogen cooling to -160°C and air chiller to -60°C to use with the standard furnace

DMTA Measurements in Reactive Atmospheres 
...containment with fume hood for in-situ investigations protects the laboratory environment.  

 

(*) là thông tin bắt buộc
(*)
(*)
(*)
hermes outlet
13/10/2023 10:46:26
After research a number of of the weblog posts in your website now, and I really like your means of blogging. I bookmarked it to my bookmark website record and can be checking back soon. Pls try my website online as effectively and let me know what you think. hermes outlet http://www.hermesbagsonline.com
supreme clothing
12/10/2023 21:11:58
I'm typically to blogging and i really recognize your content. The article has actually peaks my interest. I am going to bookmark your web site and hold checking for new information. supreme clothing http://www.supremes-clothing.us.com
birkin bag
12/10/2023 06:32:06
The next time I learn a weblog, I hope that it doesnt disappoint me as much as this one. I imply, I do know it was my choice to learn, however I truly thought youd have something fascinating to say. All I hear is a bunch of whining about something that you would repair if you werent too busy on the lookout for attention. birkin bag http://www.birkinbag.us.com
black golden goose
11/10/2023 22:51:37
I precisely desired to appreciate you all over again. I'm not certain the things that I might have made to happen in the absence of these recommendations contributed by you concerning such a theme. Certainly was a real frightening matter for me personally, however , coming across your specialized fashion you resolved that made me to weep over fulfillment. I'm just grateful for the advice and even wish you know what a great job you happen to be putting in educating other individuals using your we
cheap jordan shoes
11/10/2023 15:46:52
Your house is valueble for me. Thanks!? cheap jordan shoes http://www.cheapjordanss.us.com
The System Solution for Efficient Characterization of Polymers
0 VNĐ
The vacuum-tight thermo-microbalance for highest demands
0 VNĐ
Thermal Analysis
0 VNĐ
0 VNĐ
0 VNĐ
0 VNĐ
0 VNĐ
0 VNĐ
0 VNĐ
0 VNĐ
0 VNĐ
0 VNĐ