VN EN
 
  0941 827 888 Thứ 2-7 : 8-20H;
Chủ nhật : 8-17H
 
 
  [email protected] Trả lời 30' trong giờ hành chính  

 

Email
Mật khẩu
Trang chủ
EFC 3610 - Frequency Converter
Giá bán: 0 VNĐ/cái
Số lượng
Giá thị trường: 0 VNĐ /cái Tiết kiệm: 0.0 %

Frequency converter

EFC 3610

 

 
   
  • Power range 1 x AC 230 V 0.4 kW to 3 x AC 400 V 22.0 kW
  • Integrated brake chopper and mains filter
  • Integrated operating panel for simple, fast commissioning
  • Expandability through I/O and fieldbus modules

 

 
Search
   
Search
 
Documentation  

Instructions   
PDF version  

PDF version   

Technical dataDimensionsCADDownloadOrder details

 
  EFC3610-0K40-1P2 EFC3610-0K75-1P2 EFC3610-1K50-1P2 EFC3610-2K20-1P2 EFC3610-0K40-3P4 EFC3610-0K75-3P4 EFC3610-1K50-3P4 EFC3610-2K20-3P4
Performance data
Rated output
HD operation
[kW] 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2
Continuous rated current
HD operation
[A] 2.4 4.1 7.3 10.1 1.3 2.3 4 5.6
Motor rated voltage

Three phase, 0 V ... mains voltage

Output frequency

0 ... 400 Hz

Mains voltage 1 AC 1 AC 200 … 240 V (-10 % / +10 %) -
3 AC - 3 AC 380 … 480 V (-15 % / +10 %)
Frequency

50 ... 60 Hz (±5 %)

Overload capacity
HD operation

150 % for 60 s, 200 % for 1 s

Brake chopper / resistor
Braking resistance

External

Brake chopper

Internal up to 22 kW

Ambient conditions
Permissible temperature (operation)

-10 ... +45 °C (Derating 1.5 % of the output power per 1 °C from 45 ... 55 °C)

Permissible relative humidity (operation)

< 90 % (no condensation)

Max. installation height

1000 m (> 1000 m Derating 1 % of the output power pro 100 m)

Protection category

IP 20

Functions
Control technology

V/f

Pulse width modulation (PWM), adjustable in 1 kHz steps [kHz]

1 ... 15

Speed control range Without pulse generator

1 : 50

Start-up torque V/f

100% at 1.5 Hz; 150% at 3 Hz

Frequency resolution Digital

0.01 Hz

Analog

1/1000 of the output frequency

V/f curve

linear, quadratic, freely definable

Ramps

linear, S-curve

DC disc brake Start frequency

0 ... 50 Hz

Braking time

0 ... 10 s

Automatic PWM frequency adjustment

load-dependent adaptation of PWM frequency

Integrated control

integrated step switching mechanism

Frequency setting tolerance Analog

0.4 %

Digital

0.04 %

Controller

PID

Bus systems

Modbus RTU (with Multi-Ethernet Modbus TCP)

PROFIBUS, CANopen, Multi-Ethernet (ext. options)

Status messages via digital outputs

Operation, target value achieved, etc.

Number of digital inputs
24 VDC

5 (of which 1x pulse train 50 kHz)

Number of digital outputs
24 VDC / 50 mA

1 (pulse train 32 kHz)

Number of relay outputs 
230 VAC / 30 VDC / 3 A

1

Number of analog inputs
0 ... 10 V or 0 ... 20 mA

2

Number of analog outputs
0 ... 10 V or 0 ... 20 mA

1

Display

Dust cover with 4 diagnostic LED

LED 5 digit (optional)

LCD (optional)

Status LED

Rotation direction and operating status

Weight
Weight [kg] 1.5 1.9 2.6 1.5 1.9
Norms and Standards
Certification

CE
UL
cUL
EAC
C-Tick (RCM)

 
  EFC3610-3K00-3P4 EFC3610-4K00-3P4 EFC3610-5K50-3P4 EFC3610-7K50-3P4 EFC3610-11K0-3P4 EFC3610-15K0-3P4 EFC3610-18K5-3P4 EFC3610-22K0-3P4
Performance data
Rated output
HD operation
[kW] 3 4 5.5 7.5 11 15 18.5 22
Rated output
ND operation
[kW] - 7.5 11 15 18.5 22 30
Continuous rated current
HD operation
[A] 7.4 9.7 12.7 16.8 24.3 32.4 39.2 45
Continuous rated current
ND operation
[A] - 16.8 24.3 32.4 39.2 45 60.8
Motor rated voltage

Three phase, 0 V ... mains voltage

Output frequency

0 ... 400 Hz

Mains voltage 3 AC

3 AC 380 … 480 V (-15 % / +10 %)

Frequency

50 ... 60 Hz (±5 %)

Overload capacity
HD operation

150 % for 60 s, 200 % for 1 s

Brake chopper / resistor
Braking resistance

External

Brake chopper

Internal up to 22 kW

Ambient conditions
Permissible temperature (operation)

-10 ... +45 °C (Derating 1.5 % of the output power per 1 °C from 45 ... 55 °C)

Permissible relative humidity (operation)

< 90 % (no condensation)

Max. installation height

1000 m (> 1000 m Derating 1 % of the output power pro 100 m)

Protection category

IP 20

Functions
Control technology

V/f

Pulse width modulation (PWM), adjustable in 1 kHz steps [kHz]

1 ... 15

Speed control range Without pulse generator

1 : 50

Start-up torque V/f

100% at 1.5 Hz; 150% at 3 Hz

Frequency resolution Digital

0.01 Hz

Analog

1/1000 of the output frequency

V/f curve

linear, quadratic, freely definable

Ramps

linear, S-curve

DC disc brake Start frequency

0 ... 50 Hz

Braking time

0 ... 10 s

Automatic PWM frequency adjustment

load-dependent adaptation of PWM frequency

Integrated control

integrated step switching mechanism

Frequency setting tolerance Analog

0.4 %

Digital

0.04 %

Controller

PID

Bus systems

Modbus RTU (with Multi-Ethernet Modbus TCP)

PROFIBUS, CANopen, Multi-Ethernet (ext. options)

Status messages via digital outputs

Operation, target value achieved, etc.

Number of digital inputs
24 VDC

5 (of which 1x pulse train 50 kHz)

Number of digital outputs
24 VDC / 50 mA

1 (pulse train 32 kHz)

Number of relay outputs 
230 VAC / 30 VDC / 3 A

1

Number of analog inputs
0 ... 10 V or 0 ... 20 mA

2

Number of analog outputs
0 ... 10 V or 0 ... 20 mA

1

Display

Dust cover with 4 diagnostic LED

LED 5 digit (optional)

LCD (optional)

Status LED

Rotation direction and operating status

Weight
Weight [kg] 2.6 3.9 4.3 5.7 6.4 8 8.5
Norms and Standards
Certification

CE
UL
cUL
EAC
C-Tick (RCM)

 

Electric Drives and Controls, Online Version, Last Updated #version#

© Bosch Rexroth AG, Subject to Change

(*) là thông tin bắt buộc
(*)
(*)
(*)
synthroidtro.com
07/05/2023 11:36:38
levothyroxine 75 mcg tablet Some natural remedies that have been used to manage hypothyroidism include dietary changes, such as increasing iodine-rich foods in the diet, and taking supplements such as selenium or zinc. These remedies may help to support thyroid function, but should only be used under the guidance of a doctor.
synthroidtro.com
07/05/2023 10:40:13
levothyroxine 50 mcg tablet cost In some cases, the doctor may need to adjust the medication dose or prescribe additional medications to manage side effects such as headaches, nervousness, and weight changes. Patients should report any changes in symptoms or side effects to their doctor, and should not adjust their medication dose or stop taking the medication without first consulting with the doctor.
synthroiduuu.com
07/05/2023 08:22:55
synthroid 50 mg Synthroid contains the active ingredient levothyroxine sodium, which is identical to the natural thyroid hormone produced by the body.
synthroiduuu
07/05/2023 08:04:15
over the counter thyroid medicine Patients who are taking Synthroid or levothyroxine should inform their healthcare provider before undergoing any diagnostic tests, as these medications can affect the results of certain blood tests, such as thyroid function tests.
synthroidvbo
06/05/2023 23:46:46
taking synthroid with other medications In addition to treating hypothyroidism, Synthroid and levothyroxine may also be used to diagnose and manage certain types of thyroid cancer.
Frequency Converter
0 VNĐ
Frequency Converter
0 VNĐ
Frequency Converter
0 VNĐ